Use an LVL beam selection worksheet to collect a named member’s span, loads, supports, product data and order needs before requesting a section recommendation. Tie each value to a unit and document issue. Leave unknown values blank and flag them To confirm. This SENSO download provides editable Excel and fillable PDF forms for preliminary review. It does not calculate beam capacity, choose a section or replace qualified structural design.

Download the LVL beam selection worksheet
Choose the Excel file for editing and the PDF for a shared project record. Both use revision M02-08 R1. The workbook has three tabs: Worksheet, Loads and Product evidence. The PDF has four fillable pages and a dimension sketch.
Use one file per member configuration. Then keep the same member ID on every sheet and attachment. Save a new request revision when geometry, loads or product choices change.
Record span inputs and bearing separately
First, identify whether the member acts as a joist, bearer, roof beam or header. Next, mark its supports and load path. A clear span alone cannot define the required section.
| Input group | Record and unit | Required context |
|---|---|---|
| Span | Clear span and design span, mm | Definition and marked drawing issue |
| Section and length | Width × depth and order length, mm | Proposed product, orientation and plies |
| Supports | Left and right bearing, mm | Support material, hanger and restraint details |
| Load collection | Spacing and supported width, mm | Member role and load path |
| Actions | Area kPa, line kN/m or point kN | Direction, location, duration and load basis |
| Movement | Deflection limit, mm or span ratio | Load component, time condition and source |
| Use and supply | Exposure, treatment, quantity and delivery | Project requirement and supplier response |
These are input fields and units, not product specifications or allowable values.
In particular, do not copy overall order length into the span field. The PDF sketch separates support contacts from the opening. Also, check the exact span definition in the current matched LVL beam span tables. Use the LVL beam sizes guide for section planning.

Keep product evidence separate from test results
LVL means laminated veneer lumber. It uses bonded wood veneers oriented mainly along the member. APA’s structural composite lumber guidance explains the product family and its uses. However, structural properties belong to the named product and its qualification.
| Evidence type | What it can establish | What still needs checking |
|---|---|---|
| Product specification | Named grade, section and stated use | Issue, tolerances and supply identity |
| Declared structural data | Product strength and stiffness basis | Units, axis, conditions and design rules |
| Standard requirement | Rules within the standard’s scope | Adopted edition and product conformity |
| Typical value or single test | General context or one measured result | Whether it qualifies as design data |
Stiffness affects movement, while strength values address different failure checks. Therefore, record bending, shear and bearing data separately. A higher stiffness label does not establish the whole beam’s capacity. For comparisons, keep grade, section and use linked in our structural LVL decision guide.
Use the load checklist to expose missing inputs
For example, a drawing may show a truss reaction without its magnitude. Record the point-load location, leave its value blank and assign an owner to obtain it. Entering 0 kN would claim a known zero force.
| Input status | Meaning | Next action |
|---|---|---|
| To confirm | Value or source remains missing | Keep it open and name a contact |
| Provided | Input and source recorded | Submit for the required review |
| Not applicable | Item excluded with a reason | Record who confirmed the exclusion |
These statuses track information only. Even a fully completed LVL beam selection worksheet needs a separate design response and order release.

Check standards, use limits and the supplier
For Australian projects, AS/NZS 4357.0:2022 covers structural LVL product requirements. AS 1720.1 addresses timber design methods. The project designer must confirm adopted editions and amendments. A standard number on a quote does not prove product certification.
Request the evidence ID, issuer, current status, product and plant scope. Also, match it to the supplied marking. EWPAA’s LVL conformance note explains why product identity and declared properties matter.
Confirm exposure, treatment, moisture requirements and connection details as well. Do not assume a floor or header product suits permanent weather exposure, formwork or scaffolding. Each use needs matching evidence.
LVL beam selection worksheet questions
Will this LVL beam selection worksheet recommend a beam size?
No. It records inputs for a qualified review. It contains no span, load-combination or capacity calculator.
Can I send it before all loads are available?
Yes, for preliminary discussion. Flag missing loads and identify who will supply them. Keep final selection pending.
Can I enter imperial units in the LVL beam selection worksheet?
Only after clearly relabelling the affected units and confirming conversions. The default dimension fields use millimetres.
Does Provided mean the beam is approved?
No. It means an input and its source have been recorded. Store the qualified design response separately.
Can I reuse the form for another product grade?
Create a revised request. Then replace the product evidence and have the changed selection checked.
What should accompany an RFQ?
Attach drawings, member IDs, quantities, ordered lengths, product evidence and open questions. State currency, price unit, delivery term and destination.
What happens when a support or load changes?
Update the drawing and request revision. Resubmit the affected member for qualified review before order release or site changes.
Send the span, load and support conditions for preliminary product guidance. Contact SENSO with your completed LVL beam selection worksheet and drawings. We can review the supply request and confirm the proposed product information. Final structural design requires qualified verification.
Post time: Nov-16-2026